Dual-Output CIM-1200H/N  
 
  Overview   |   Technical Data
 
     
 
DC Input (per Channel)
60 / 72 Cell Panel
Battery
Recommended Input Power 250W - 330W 48V, 50AH - 300AH
Operating Input DC Voltage Range 15V - 58V 47V - 58V
Peak Power Performance Range 30V - 58V 48V - 58V
Maximum Input DC Voltage / Current 58V / 9A 58V / 9A
Maximum Input Power 300W 300W
Minimum Starting Voltage 20V 47V
Compatible Solar Panels Most 60-Cell and 72-Cell PV Solar Panels
Compatible Batteries 48V Lead-Acid Deep-Cycle AGM or Lithium-Ion Pack
AC Output
H Output Port
N Output Port
Rated Output Power / Peak Output Power 960W / 1150W 960W / 1150W
Nominal Output Current (RMS) 4A - 8A 8A
Maximum Output Current (RMS) 9.5A 9.5A
Nominal Output Voltage / Range 100V - 240V /
(10V - 264V)
120V
(108V - 132V)
Nominal Frequency / Range 60Hz
(59.5Hz - 60.5Hz)
60Hz
(59.5Hz - 60.5Hz)
Power Factor >0.95
Efficiency
Data
Peak Efficiency / MPPT Tracking 96%   (99%)
Mechanical Data
SI
U.S.
Ambient Temperature Range -40°C to +65°C -40°F to +149°F
Internal Operating Temperature Range -40°C to +88°C -40°F to +190°F
Dimensions w/o mounting bracket (L x H x W) 32cm x 24cm x 5.8cm 12.5" x 9.5" x 2.3"
Weight 6.5 kg 14.25 lbs
Cooling / Enclosure Natural Convection, No Fan / Potted
DC / AC Wire and Connectors MC-4 or Compatible / Weiland RST 3-Conductor
Features and Compliance
Data
Safety and EMC Compliance UL1741/IEEE1547 (E113426),
CSA 107.1, FCC Part 15 Class A
DC Ground Fault Detector Interrupter (GFDI) Built-In
Standard Warranty 3 Years (Extended Warranty Available)
Enclosure Environment Rating / Safety Outdoor - NEMA 6 / Transformer Isolated Circuits
Built-in Battery Over Discharge Protection Low Voltage Disconnect (LVD) on Battery Channels.
 
     
     
   
     
     
     
     
 
 

© 2018 CyboEnergy, Inc.