DC Input (per Channel) |
60-66 Cell
/ 120 Half-Cell
|
72 Cell Panel*
|
Supported Input Power |
250W - 400W |
300W - 450W |
Operating Input DC Voltage Range |
18V - 60V |
18V - 60V |
Peak Power Performance Range |
30V - 60V |
30V - 60V |
Maximum Input DC Voltage / Current |
60V / 11.5A |
60V / 11.5A |
Maximum Input Power |
330W |
330W |
Minimum Starting Voltage |
20V |
20V |
|
|
|
AC Output |
Data |
Rated Output Power / Peak Output Power |
960W / 1250W |
Maximum Output Current (RMS) |
10.5A (RMS - Root Mean Square) |
Nominal Operating AC Output Voltage / Range |
100V - 240V (10V - 264V, Single-Phase) |
Nominal Frequency / Range |
60Hz (59.5Hz-60.5Hz) or 50Hz (49.5-50.5Hz) |
|
|
|
Efficiency |
Data |
Peak Efficiency / MPPT Tracking |
96% (99%) |
|
|
|
Mechanical Data |
SI |
U.S. |
Ambient Temperature Range |
-40°C to +65°C |
-40°F to +149°F |
Internal Operating Temperature Range |
-40°C to +88°C |
-40°F to +190°F |
Dimensions w/o mounting bracket (L x H x W) |
32cm x 24cm x 5.8cm |
12.5" x 9.5" x 2.3" |
Weight |
6.5 kg |
14.25 lbs |
Cooling / Enclosure |
Natural Convection, No Fan / Potted |
DC Wire / AC Wire |
1-2 Feet DC Wires /
12 Feet AC Wires (THHN), Copper |
|
|
|
Features and Compliance |
Data |
Safety and EMC Compliance |
UL1741/IEEE1547 (E113426),
CSA 107.1, FCC Part 15 Class A |
Rapid Shutdown |
Complies with NEC 2014/2017 690.12. |
DC Ground Fault Detector Interrupter (GFDI) |
Built-In |
Standard Warranty |
3 Years (Extended Warranty Available) |
Enclosure Environment Rating / Safety |
Outdoor - NEMA 6 / Transformer Isolated Circuits |