DC Input (per Channel) |
60 / 66 Cell Panel |
72 Cell Panel |
Battery * |
Supported Input Power |
250W – 400W |
300W – 450W |
48V, 50AH – 300AH |
Operating Input DC Voltage Range |
18V – 60V |
18V – 60V |
47V – 60V |
Peak Power Performance Range |
30V – 60V |
30V – 60V |
48V – 60V |
Maximum Input DC Voltage / Current |
60V / 11.5A |
60V / 11.5A |
60V / 11.5A |
Maximum Input Power |
330W |
330W |
330W |
Minimum Starting Voltage |
20V |
20V |
47V |
Compatible Batteries |
48V Lead-Acid Deep-Cycle AGM or Lithium-Ion Pack |
|
|
|
AC Output (per Inverter) |
Data |
Rated Output Power / Peak Output Power |
960W / 1250W |
Maximum Startup Surge Power for 12 Seconds |
1500W (Max Surge DC Power = 400W per Channel) |
Nominal Output Current (RMS) |
4A (RMS — Root Mean Square) |
Nominal Output Voltage / Range |
240V (216V – 264V, Single-Phase) |
Nominal Frequency / Range |
60Hz (59.5Hz – 60.5Hz) |
Power Factor |
>0.95 |
|
|
|
Efficiency |
Data |
Peak Efficiency / MPPT Tracking |
96% (99%) |
|
|
|
Mechanical Data |
SI |
U.S. |
Ambient Temperature Range |
-40°C to +65°C |
-40°F to +149°F |
Internal Operating Temperature Range |
-40°C to +88°C |
-40°F to +190°F |
Dimensions w/o mounting bracket (L x H x W) |
32cm x 24cm x 5.8cm |
12.5" x 9.5" x 2.3" |
Weight |
6.5 kg |
14.25 lbs |
Cooling / Enclosure |
Natural Convection, No Fan / Potted |
DC Wire / AC Wire |
1-2 Feet DC Wires / 12 Feet AC Wires (THHN), Copper |
|
|
|
Features and Compliance |
Data |
Safety and EMC Compliance |
UL1741/IEEE1547 (E113426), CSA 107.1, FCC Part 15 Class A. |
Rapid Shutdown |
Complies with NEC2014/2017 690.12. |
DC Ground Fault Detector Interrupter (GFDI) |
Built-In |
Standard Warranty |
3 Years (Extended Warranty Available) |
Enclosure Environment Rating / Safety |
Outdoor - NEMA 6 / Transformer Isolated Circuits |
Built-in Battery Over Discharge Protection |
Low Voltage Disconnect (LVD) on Battery Channels |